CONTACTEZ-NOUS DÈS MAINTENANT POUR RECEVOIR UN DEVIS RAPIDE, UN SUPPORT D'ÉCHANTILLONNAGE ET UNE GARANTIE DE SERVICE D'INGÉNIERIE.

Solid aluminum panel vs ACP is first a fire-safety question, then a design and cost question. On high-rise buildings, a solid aluminum panel is the simpler choice: it is non-combustible metal all the way through. Aluminum composite panel (ACP) can still work on high-rise facades, but only with a fire-rated or A2 core, the right test reports and a tested wall system.
This guide compares the two by fire safety, flatness, shapes, durability, weight and cost, so you can choose the right panel for each part of your facade.
A solid aluminum panel (also called aluminum single skin panel or aluminum veneer) is one sheet of aluminum, usually 2.0–3.0 mm thick, folded at the edges and fixed to the subframe with stiffeners and brackets.
An ACP is a sandwich: two thin aluminum skins, typically about 0.5 mm each, bonded to a core about 3 mm thick. The core decides how it behaves in a fire:
| Panneau en aluminium massif | ACP (PE core) | ACP (FR / A2 core) | |
|---|---|---|---|
| Fire behavior | Non-combustible metal | Combustible core | Limited combustibility; check the test report |
| High-rise use | Oui | Banned or restricted in many markets | Allowed where the tested system complies |
| Flatness on large panels | Good with stiffeners | Very good | Very good |
| Curves, 3D shapes, perforation | Excellent | Limité | Limité |
| Dent resistance | High (2.0–3.0 mm skin) | Low (about 0.5 mm skin) | Low (about 0.5 mm skin) |
| Typical weight, 4 mm ACP vs 2.5 mm solid | About 6.8 kg/m² plus stiffeners | About 5.5 kg/m² | About 7.5–8 kg/m² |
| Relative cost | Moyen | Lowest | Close to solid panel |
| Recycling | Easy, pure aluminum | Needs core separation | Needs core separation |
ACP weights are typical industry values and vary by brand. For solid panel weights and prices by thickness, see our guide to aluminum panel thickness.

The fire risk of ACP comes from its core, not its aluminum skins. A polyethylene core can melt and burn, and fire can spread up the facade. Since the Grenfell Tower fire in London in 2017, many countries have restricted combustible cladding:
A solid aluminum panel avoids this question. The panel itself contains no combustible core, and our PVDF-coated facade panels are tested to fire class A2. You still need to check the coating, insulation and membranes behind it, because codes judge the whole wall. Our guide to aluminum ceiling fire ratings explains A1, A2-s1,d0 and ASTM E84 classes for metal panels.
ACP is very flat because the core stiffens the thin skins. That makes it popular for large, flat signage-style facades.
Solid panels need stiffeners on large sizes to stay flat. With good design, a 2.5 or 3.0 mm panel meets the flatness limit of ≤ 2 mm per metre in China’s GB/T 23443-2024. The advantage is in shapes: solid aluminum can be curved, double-curved, deeply perforated, embossed and welded at the corners, which ACP cannot do well.
With a 2.0–3.0 mm skin, solid panels resist dents from hail, ladders and impact at ground level. ACP’s thin skins dent more easily, and poor bonding can lead to delamination over time.
Both can use the same high-performance finishes; our PVDF-coated solid panels carry a 15-year coating warranty. Compare options in Finition de surface en PVDF et fluorocarbon coating vs PVDF coating. For coastal sites, see aluminum curtain wall for coastal climates.

PE-core ACP is the cheapest option, which is why it was so widely used. But on high-rise buildings, it is no longer an option in many markets. Once you compare FR or A2 ACP with a 2.5 mm solid panel, the price gap becomes small, and the solid panel adds shape freedom, dent resistance and easy recycling.
As a guide, PVDF-coated solid panels cost about USD 30–38/m² FOB for 2.5 mm et USD 35–45/m² for 3.0 mm (November 2026, standard orders of 300 m² or more).
Choose a solid aluminum panel when:
ACP can make sense when:
Guangzhou Women and Children’s Medical Center, Huadu Campus, China: an 81.2 m, 16-storey hospital tower with about 33,000 m² of curtain wall. For a hospital at this height, with curved panel bands wrapping the corners, we supplied 3.0 mm solid aluminum panels: non-combustible, and able to follow the curves.
Shopping mall, Bangladesh: the client first planned ACP for the 3,000 m² facade. Concerned about fire safety, they switched to A2-rated solid aluminum panels from us, with a 15-year PVDF coating warranty.
Is ACP banned? Not everywhere. PE-core ACP is banned or restricted on many buildings in England, Australia and the UAE, and in the US it needs an NFPA 285-tested wall above 40 ft. FR and A2-core ACP remain in use where the tested system complies.
Is a solid aluminum panel fireproof? It does not burn, because it has no combustible core. Fire performance of the whole wall still depends on insulation, membranes and the tested assembly.
Which is lighter, ACP or solid aluminum panel? PE-core ACP is lighter, about 5.5 kg/m² for 4 mm. FR and A2-core ACP weigh about as much as a 2.5–3.0 mm solid panel.
Which is cheaper? PE-core ACP is cheapest. FR or A2-core ACP costs close to a solid aluminum panel.
How thick should a solid aluminum panel be? 2.5 mm for most facades and 3.0 mm for large, perforated or high-rise panels. See aluminum panel thickness.
Send us your elevations, building height and target market. We will check the cladding rules for your project and recommend the panel and thickness for each area. Browse our aluminum facade panels to start.
Related reading: aluminum facade panels · aluminum panel thickness · aluminum ceiling fire ratings · Finition de surface en PVDF